{"id":199,"date":"2024-03-07T11:29:16","date_gmt":"2024-03-07T10:29:16","guid":{"rendered":"http:\/\/www.tem.agh.edu.pl\/main_nowastrona\/?p=199"},"modified":"2024-03-07T11:55:32","modified_gmt":"2024-03-07T10:55:32","slug":"tecnai-g2-20-twin-fei","status":"publish","type":"page","link":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/tecnai-g2-20-twin-fei\/","title":{"rendered":"Tecnai G2 20 TWIN (FEI)"},"content":{"rendered":"\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/PXL_20201202_102509610-768x1024.jpg\" alt=\"\" class=\"wp-image-200\" srcset=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/PXL_20201202_102509610-768x1024.jpg 768w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/PXL_20201202_102509610-225x300.jpg 225w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/PXL_20201202_102509610-1152x1536.jpg 1152w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/PXL_20201202_102509610-1536x2048.jpg 1536w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/PXL_20201202_102509610-676x901.jpg 676w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/PXL_20201202_102509610-scaled.jpg 1920w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Data sheet:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes has-small-font-size\"><table><tbody><tr><td>TEM point resolution (nm)<\/td><td>0.27<\/td><\/tr><tr><td>TEM line resolution (nm)<\/td><td>0.144<\/td><\/tr><tr><td>Minimum focus step (nm)<\/td><td>2<\/td><\/tr><tr><td>TEM magnification range<\/td><td>25 x &#8211; 700 kx<\/td><\/tr><tr><td>Camera length (mm)<\/td><td>52 &#8211; 6,000<\/td><\/tr><tr><td>Maximum diffraction angle<\/td><td>\u00b110\u00b0<\/td><\/tr><tr><td>STEM resolution (nm)<\/td><td>1.0<\/td><\/tr><tr><td>STEM magnification range<\/td><td>100 x &#8211; 5 Mx<\/td><\/tr><tr><td>Maximum tilt angle with double-tilt holder<\/td><td>\u00b170\u00b0<\/td><\/tr><tr><td>Maximum tilt angle with tomography holder<\/td><td>\u00b180\u00b0<\/td><\/tr><tr><td>EDS solid angle (srad)<\/td><td>0.13<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Electron source<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Flexible high tension (20, 40, 80, 120, 160, 200 kV and values in between)<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">LaB6 emitter <\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Imaging <\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">High tilt and large field of view (\u00b1 70\u00b0 tilt for TWIN and double-tilt holder)<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Coma-free alignment for high resolution objective lens centering<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Ranged, rotation-free magnification and diffraction series<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Magnification reproducible within \u00b1 1.5%<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\"> Embedded CCD and\/or energy filter<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Plate camera with 56 sheets of film <\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Diffraction<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Wide range of diffraction techniques, from coherent illumination for selected area diffraction or micro-diffraction to highly convergent (large angle) beam diffraction<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Energy filtered diffraction down to low camera length (&lt;200 mm): maximum visible diffraction angle \u00b1 125 mrad STEM<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">Fully digital scan system \u2022 Bright Field and High Angle Annular Dark Field mode<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-small-font-size\">EDX microanalysis TIAPrecession electron diffraction DigiStar and ASTAR for orientation- and phase mapping<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"202\" src=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113133-1024x768.jpg\" alt=\"\" class=\"wp-image-202\" srcset=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113133-1024x768.jpg 1024w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113133-300x225.jpg 300w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113133-768x576.jpg 768w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113133-1536x1152.jpg 1536w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113133-2048x1536.jpg 2048w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113133-676x507.jpg 676w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"206\" src=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113217-1024x768.jpg\" alt=\"\" class=\"wp-image-206\" srcset=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113217-1024x768.jpg 1024w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113217-300x225.jpg 300w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113217-768x576.jpg 768w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113217-1536x1152.jpg 1536w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113217-2048x1536.jpg 2048w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113217-676x507.jpg 676w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"205\" src=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113309-1024x768.jpg\" alt=\"\" class=\"wp-image-205\" srcset=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113309-1024x768.jpg 1024w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113309-300x225.jpg 300w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113309-768x576.jpg 768w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113309-1536x1152.jpg 1536w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113309-2048x1536.jpg 2048w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/20240307_113309-676x507.jpg 676w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" data-id=\"204\" src=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-576x1024.jpg\" alt=\"\" class=\"wp-image-204\" srcset=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-576x1024.jpg 576w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-169x300.jpg 169w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-768x1365.jpg 768w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-864x1536.jpg 864w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-1152x2048.jpg 1152w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-676x1201.jpg 676w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06327-scaled.jpg 1440w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"576\" height=\"1024\" data-id=\"203\" src=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-576x1024.jpg\" alt=\"\" class=\"wp-image-203\" srcset=\"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-576x1024.jpg 576w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-169x300.jpg 169w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-768x1365.jpg 768w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-864x1536.jpg 864w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-1152x2048.jpg 1152w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-676x1201.jpg 676w, https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-content\/uploads\/2024\/03\/DSC06329-scaled.jpg 1440w\" sizes=\"(max-width: 576px) 100vw, 576px\" \/><\/figure>\n<\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Data sheet: TEM point resolution (nm) 0.27 TEM line resolution (nm) 0.144 Minimum focus step (nm) 2 TEM magnification range 25 x &#8211; 700 kx Camera length (mm) 52 &#8211; 6,000 Maximum diffraction angle \u00b110\u00b0 STEM resolution (nm) 1.0 STEM magnification range 100 x &#8211; 5 Mx Maximum tilt angle with double-tilt holder \u00b170\u00b0 Maximum [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-199","page","type-page","status-publish","hentry","post-preview"],"_links":{"self":[{"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/pages\/199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/comments?post=199"}],"version-history":[{"count":2,"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/pages\/199\/revisions"}],"predecessor-version":[{"id":208,"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/pages\/199\/revisions\/208"}],"wp:attachment":[{"href":"https:\/\/www.tem.agh.edu.pl\/main_nowastrona\/wp-json\/wp\/v2\/media?parent=199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}